Online HERS Rater Certification Training Course
YOUR #1 ONLINE HERS RATER
 TRAINING RESOURCE
  • HOME
  • HERS PRACTICE EXAMS
    • FREE HERS RATER EXAM QUESTIONS
  • NEWBIES
    • WHAT DOES IT LOOK LIKE?
    • HOW DO I DO...?
    • HOW TO CHOOSE A HERS RATER TRAINING CENTER
    • STEP-BY-STEP GUIDE
  • STUDY GUIDES
    • HERS RATER WRITTEN EXAM >
      • Section 1 Building Science Fundamentals >
        • 1a. Basic Terms & Definitions >
          • 1. Airflow in Buildings
          • 2. Equipment Efficiencies
          • 3. Power and Energy
          • 4. Effective Leakage Area
          • 5. Area Weighted R-Value
          • 6. Baseload / Seasonal Energy Use
          • 7. Driving Forces (Including Natural and Mechanical)
          • 8. Behavior of Radiation
          • 9. Thermal Resistance / Transmittance: R and U Values
          • 10. Latent / Sensible Heat
          • 11. Total Equivalent Length
          • 12. Dehumidification / Humidification
          • 13. Convert Pressure Units
          • 14. Thermal Bridges
          • 15. Pressure Boundary
          • 16. Stack Effect
          • 17. Exfiltration and Infiltration
          • 18. Natural / Mechanical Ventilation
          • 19. Net Free Area
          • 20. Input & Output Capacity
          • 21. Peak Electrical Demand
          • 22. Permeability and Perm Rating
          • 23. Standby Loss
          • 24. IAQ (indoor air quality): Moisture, CO, Dust
        • 1b. Principals of Energy, Air & Moisture Thermodynamics >
          • 1. Thermodynamics: Conduction, Convection, Radiation, ΔT
          • 2. Factors That Affect Insulation Performance
          • 3. House Pressurization/Depressurization by Various Forces
          • 4. Heat Gain / Loss
          • 5. Power and Energy
          • 6. Moisture Transport Mechanisms
          • 7. Identify Areas of Highest Relative Humidity
          • 8. Principles of Combustion
        • 1c. Combustion Safety >
          • 1. Combustion Analysis
          • 2. Carbon Monoxide (CO) Testing
          • 3. Combustion Appliance Venting, Draft, Combustion Air & Sizing
          • 4. Understand Combustion Safety Issues
      • Section 2 Buildings and Their Systems >
        • 2a. Building Components >
          • 1. Identify basic duct configurations and components
          • 2. Identify Basic Hydronic Distribution Configurations and Components
          • 3. Identify Basic Structural Components of Residential Construction
          • 4. Thermal Boundaries and Insulation Applications
          • 5. Basic Electrical Components and Safety Considerations
          • 6. Basic Fuel Delivery Systems and Safety Considerations
          • 7. Basic bulk water management components (drainage plumbing gutters sumps etc)
          • 8. Vapor barriers/retarders
          • 9. Radiant Barrier Principles and Installations
          • 10. Understand Fenestration Types and Efficiencies
          • 11. Understand Issues Involved With Basements, Crawlspaces, Slabs, Attics, Attached Garages, Interstitial Cavities, and Bypasses
          • 12. Understand Issues Involved With Ventilation Equipment
          • Understand Basic Heating / Cooling Equipment Components Controls and Operation
          • Understand Basic DHW Equipment Components Controls and Operation
          • Identify Common Mechanical Safety Controls
          • Identify Insulation Types and R-Values
          • Understand Various Mechanical Ventilation Equipment and Strategies: Spot, ERV, HRV
        • Conservation Strategies >
          • Appropriate Insulation Applications and Installation Based On Existing Conditions
          • Opportunity for ENERGY STAR Lighting and Appliances
          • Identify Duct Sealing Opportunities and Applications
          • Understand Importance of Air Leakage Control and Remediation Procedures
          • Blower Door-Guided Air Sealing Techniques
          • Water Conservation Devices and Strategies
          • Domestic Hot Water (DHW) Conservation Strategies
          • Heating & Cooling Efficiency Applications
          • Proper Use of Modeling to Determine Heating and Cooling Equipment Sizing and Appropriate Energy
          • Understand the Use of Utility History Analysis in Conservation Strategies
          • Appropriate Applications For Sealed Crawlspaces Basements and Attics
          • Identify / Understand High Density Cellulose
          • Appropriate Applications for Fenestration Upgrades Including Modification or Replacement
        • Comprehensive Building Assessment Process >
          • Determine Areas of Customer Complaints / Concerns in Interview
          • Understand / Recognize Need For Conducting Appropriate Diagnostic Procedures
          • Interaction Between Mechanical Systems, Envelope Systems and Occupant Behavior
        • Design Considerations >
          • Appropriate Insulation Applications Based On Existing Conditions
          • Understand Fire Codes as Necessary to Apply Home Performance in a Code-Approved Manner
          • Understand / Recognize Building Locations Where Opportunities for Retrofit Materials
          • Understand Climate Specific Concerns
          • Understand Indoor Environment Considerations for the Environmentally Sensitive
          • Understand Impact of Building Orientation, Landscape Drainage, and Grading
          • Opportunity Potential Renewable Energy Applications: Geothermal, Photovoltaic, Wind
          • Understand Impact of Shading on Heating / Cooling Loads
          • Awareness for Solar Gain Reduction / Solar Gain Opportunities
          • Understand Need for Modeling Various Options For Efficiency Upgrades
      • Measurement & Verification of Building Performance >
        • Measurement & Verification of Building Performance >
          • Air Leakage Test Results
          • Understand Building Shell / Envelope Leakage
          • Apply Fundamental Construction Mathematics and Unit Conversions
          • Calculate Building Tightness Levels (Minimum Ventilation Requirements)
          • Calculate Heating Degree Days and Cooling Degree Days
          • Identify Proper Appliance and Combustion Appliance Venting
          • Ventilation calculations and strategies
          • Proper methods for identifying / testing fuel leaks
          • Blower door setup, accurate measurement and interpretation of results
          • Combustion Appliance Zone (CAZ): depressurization, spillage, draft, Carbon Monoxide (ambient and flue)
          • Carbon Monoxide (CO) evaluation: ambient
          • Proper applications and use of temperature measuring devices
          • Pressure pan and room to room pressure diagnostics
          • Recognize contributing factors to comfort problems
          • Inspect for areas containing moisture or bulk water in undesirable locations
          • Understand and inspect for basic electric safety (e.g. frayed wires, open boxes, etc)
      • RESNET HERS RATER National Standards & Project Specifications >
        • Understand applicability content and intent of BPI National Standards – Do no harm, make buildings more healthy, comfortable, durable and energy efficient
        • Recognize need for a professional local/state/national codes evaluation
        • Be able to specify appropriate materials and processes needed for building performance projects
      • Analyzing Buildings Systems >
        • Recognize need for air sealing measures and their impact on other building systems
      • Conduct and Communications >
        • Conservation strategies
        • Conservation strategies
    • HERS RATER FIELD EXAM >
      • How To Put The House Under Worst Case & CAZ
      • What's What? Pa, CFM, CFM50, CAZ, Draft, Room Pressure
      • What To Know In The Attic
      • What To Know In The House
    • BLOWER DOOR TEST >
      • Manometer Setup
    • RESNET STANDARDS >
      • RESNET Standards Decoded
  • ESSENTIALS
    • HELP, I HATE MATH!
    • AUDITOR TO CREW COMMUNICATION
    • COMMON AUDITOR / CREW MISTAKES
    • RUN LIKE HELL
    • CONTACT
  • AFTER THE EXAM
    • GROW YOUR HOME PERFORMANCE BUSINESS
    • START A HOME PERFORMANCE BUSINESS
    • FREE ENERGY AUDITOR MINI COURSE
    • RESOURCES
  • NEWSLETTER

Your Online HERS Rater Training Center

FREE HERS RATER PRACTICE EXAM

Picture

GET THE NEWSLETTER

Submit

HERS Rater Field Exam - Pa, CFM, CFM50, CAZ, Draft, Room Pressure

Term
Ambient CO


Baseline
 

Dominant duct leakage


Room pressure


Worst case





CAZ Readings






Draft







Spillage



MVR / BAS






CFM


CFM50



ACH50


Pressure pan


Zonal pressure
Unit
ppm - parts per million

Pa - pressure
 

Pa - pressure



Pa - pressure


Pa - pressure





Pa - pressure






Pa - pressure







No units, pass or fail



Cubic feet per minute - flow rate





Cubic feet per minute - flow rate

Cubic feet per minute - flow rate


No units


Pa - pressure


Pa - pressure
What it tells us
If the homeowner and ourselves are at risk during our tests

Normalizes wind and outside conditions

If there is more leakage on the supply (positive) or return (negative)


If a room is getting too pressurized and the house depressurized

Sets the home to try to make it fail while we are there to alert the homeowner. Done to: 1) get a CAZ reading and 2) perform combustion safety tests

Done under worst case conditions, in the same room as a combustion appliance (furnace, water heater, oven, dryer, central vacuum,  fireplace). CAZ reading taken WRT the outside. 

Tells us if the draft of the flue stack is strong enough to remove flue gases. Done under worst case conditions first, 1-2 feet above diverter, within 60 sec of start-up.



Test if backdrafting of combustion gases occurs.


If a home is too tight according to BPI Standards based on a 0.35 ACHN exchange rate.




The flow rate of air leakage from a home while ramping up to 50 Pa

The flow rate at 50 Pa.  This is our blower door whole house leakage number.

# of times air house air is replaced with outside air

How much duct leakage is from a duct coming out of each register.

Which zones are connected to each other, if a zone is outside or inside.
Threshold
35 ppm or lower


None


Positive pressure = more return leakage
​ 

 -3 to +3 Pa is good



More negative is better for our test, but bad for the homeowner.



See BPI Standards for limits. The more positive, the better.  




See BPI Standards for limits.  The more negative, the better.  Done under worst case conditions first, 1-2 feet above diverter, within 60 sec of start-up.

Pass or fail.  Done under worst case conditions first, within 60 sec of start-up.

If BAS > final CFM50 > (0.7 x BAS) Must recommend mech. vent.
If (0.7 x BAS) > final CFM50 Must install mech. vent.

None


See BPI Standards for BAS


None


Less than 1 Pa, the lower the less duct leakage

0 - 10 Pa Inside
11 - 39 Pa Confused
40 - 50 Pa Outside
Self check - see if you can answer these questions from memory:

  1. How are room pressures are different from worst case?
  2. How is CAZ is different from worst case?
  3. What is the formula for ACH50?
  4. What is the formula for CFM50? (Answer - there is none)
  5. What are the steps to calculate the BAS for a home?
  6. What are the steps to put a home under worst case conditions?

Next Section

Powered by Create your own unique website with customizable templates.